Your location:Home   Products   Operating Room    Ventilator    TX-GGZ-AD-I Children CPAP System Medical Ventilator
0
Shopping Cart
Delete all items
Proceed to send inquiry
*
*
*
TX-GGZ-AD-I Children CPAP System Medical Ventilator
Bubble CPAP is a sort of special medical equipment for supporting of babies’ breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies’ WOB effectively, while keeping the autonomous respiration well.
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
//www.txmedtech.com/uploadfiles/128.1.164.122/webid2093/source/202210/166615908437.jpg
Product Detail

Specification:

Model

AD-I

AD-IA

AD-II

FiO2

21%-100%(±3%)

21%-100%(±3%)

21%-100%(±3%)

CPAP

3-10cmH2O

3-10cmH2O

0-10cmH2O

Flow

2-18LPM

1-10LPM

2-18LPM

Noise

≤52 dB(A)

≤52 dB(A)

≤52 dB(A)

Power source

AC220V/110V,50-60Hz

AC220V/110V,50-60Hz

AC220V/110V,50-60Hz

Gas source

Air/Oxygen@0.3-0.4MPa

Air/Oxygen@0.3-0.4MPa

Air/Oxygen@0.3-0.4MPa

Air compressor

PN-4000(Optional)

Built-in

PN-3000(Optional)

Trolley

Yes

Optional

Yes

Technical Parameter

FIO2

21-100% (±3%)

CPAP

3-10cm H2O

Flow

0-18 LPM

Noise

≤52dB(A)

Power Source

AC 220V, 50-60Hz (Optional: AC 110V, 50-60Hz)

Gas source

Air/Oxygen@0.3-0.4MPa

Alarm

Gas supply pressure difference > 0.1MPa

Air Compressor

PN-4000 (Optional)

CPAP Generator

Yes

Trolley

Yes

Oxygen Analyzer

Optional

Application

Bubble CPAP is a sort of special medical equipment for supporting of babies’ breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies’ WOB effectively, while keeping the autonomous respiration well.

Superiority

Supply a safe and controllable FIO2;
Keep the FRC effectively;
Reduce infant’s WOB;
Reduce the need of invasive mechanical ventilation;
Supply better warm and humid gas;
Reduce the occurrence rate of the CLD;
Improve the physical sighs, such as height, weight.

Matching solution of Medical Air Compressor
Max exhausting pressure: 0.7MPa
Output pressure: 0.20MPa~0.30MPa
Flow: >25L/ruin
Noise: <52dB(A)

Performance parameter
FIO2: 21%~100>#br###Flow: 0~18LPM
CPAP pressure: 0.3~1.0kPa(3~10cmH2O)
Water capacity of Generator: 500ml or more
Alarmthe differential pressure> 0.1MPa, sound alarm


Common parameter
Pressure of oxygen and air: 0.3MPa~0.4MPa
Power: 220V AC 50Hz
Certification: ISO 13485 CE

Parts
Matching with Medical Electric Respiratory humidifier(PN-2000F/FA)
Working temperature: 30℃~37℃
Max temperature of heating plate: 85℃
Capacity of Chamber280ml(F-Adult); 230ml(FA-Infant)
Max flow: 180L/min
Max working pressure: 2kPa

CPAP Generator
1. It is easy to set the oscillating gas pressure from 3cmH2O to 10cmH2O through adjusting the CPAP pressure bar.
2. The automatic regulating mechanism of water-level ensure the constant CPAP pressure.
3. The dismountable chamber is very convenient.